Parameters
Place of Origin | Shanghai, China (Mainland) |
---|---|
Brand Name | KUB |
Certification | CE |
Model Number | FNH/27 |
Minimum Order Quantity | 10 Piece/Pieces |
Price | negotiable |
Packaging Details | Plywood pallet+carton |
Supply Ability | 500 units per month |
PRODUCT DETAILS
Type | Condenser, FNH Type Air Cooled Condenser | Application | Heater Parts |
---|---|---|---|
Name | Air Cooled Condenser | Product | Condenser |
Brand | KUB Condenser | Material | High Quality Aluminum Coating |
Condition | New | ||
High Light |
heat transfer exchanger,high efficiency heat exchanger |
PRODUCT DESCRIPTION
refrigeration ac unit Cold Room Refrigeration air cooled condenser with fan motor for Refrigerant Equipment Units
Product Description
1. Cabinet is steel plate with plastic spray, corrosion-proof and pleasant looking.
2. Mechanically expanded pipes with AL fins good heat transfer performance.
3. Air Cooled condenser have done 2.8 Mpa gas pressure and pollution clear before leave factory.
4. R22, R134A, R404A, R407C etc are optional.
5. Large air flow and low speed Built-in motor with low noise and nice looking.
6. It is widely use in big capacity condensing unit, large windward acreage and high heat exchange efficiency, with external motor.
2. Mechanically expanded pipes with AL fins good heat transfer performance.
3. Air Cooled condenser have done 2.8 Mpa gas pressure and pollution clear before leave factory.
4. R22, R134A, R404A, R407C etc are optional.
5. Large air flow and low speed Built-in motor with low noise and nice looking.
6. It is widely use in big capacity condensing unit, large windward acreage and high heat exchange efficiency, with external motor.
Model | Main parameters | Parameters of fan motor | Caliber of connecting tube | Category | ||||||
Heat removal quantity | Condensing area | Diameter of fan blade | Quantity | Total air volume | Power | Voltage | Inlet | Outlet | This company can design and produce special non-standard products for customers | |
W | ㎡ | ¢mm | N | M3/h | W | V | ¢mm | ¢mm | ||
FNH-0.6/2 | 581 | 2.0 | 200 | 1 | 430 | 35 | 220 | 10 | 10 | |
FNH-1.0/3.4 | 988 | 3.4 | 200 | 1 | 430 | 35 | 220 | 10 | 10 | |
FNH-1.2/4.0 | 1160 | 4.0 | 200 | 1 | 430 | 35 | 220 | 10 | 10 | |
FNH-1.3/4.4 | 1279 | 4.4 | 250 | 1 | 910 | 60 | 220 | 10 | 10 | |
FNH-1.5/5.2 | 1512 | 5.2 | 300 | 1 | 1530 | 75 | 220 | 10 | 10 | |
FNH-2.0/7 | 2035 | 7.0 | 300 | 1 | 1530 | 75 | 220 | 12 | 12 | |
FNH-2.4/8.4 | 2436 | 8.4 | 300 | 1 | 1530 | 75 | 220 | 12 | 12 | |
FNH-3.1/10.6 | 3074 | 10.6 | 300 | 1 | 1530 | 75 | 220 | 12 | 12 | |
FNH-2.9/10 | 2900 | 10 | 350 | 1 | 1800 | 90 | 380 | 16 | 12 | |
FNH-3.5/12 | 3480 | 12 | 350 | 1 | 1800 | 120 | 380 | 16 | 12 | |
FNH-4.4/15 | 4350 | 15 | 350 | 1 | 1800 | 120 | 380 | 16 | 12 | |
FNH-5.2/18 | 5220 | 18 | 400 | 1 | 3000 | 120 | 380 | 16 | 12 | |
FNH-6.4/22A | 6380 | 22 | 400 | 1 | 3000 | 120 | 380 | 16 | 12 | |
FNH-7.8/27 | 7830 | 27 | 400 | 1 | 3000 | 120 | 380 | 19 | 16 | |
FNH-6.4/22B | 6380 | 22 | 350 | 2 | 3600 | 2*120 | 380 | 16 | 12 | |
FNH-8.1/28 | 8120 | 28 | 350 | 2 | 3600 | 2*120 | 380 | 19 | 14 | |
FNH-9.6/33 | 9570 | 33 | 400 | 2 | 6000 | 2*120 | 380 | 19 | 14 | |
FNH-12.2/42 | 12180 | 42 | 400 | 2 | 6000 | 2*120 | 380 | 19 | 16 | |
FNH-15/52 | 15080 | 52 | 400 | 2 | 6000 | 2*120 | 380 | 19 | 16 | |
FNH-17/60 | 17400 | 60 | 450 | 2 | 9000 | 2*180 | 380 | 22 | 19 | |
FNH-20/70 | 20300 | 70 | 450 | 2 | 9000 | 2*180 | 380 | 25 | 19 | |
FNH-23/80 | 23200 | 80 | 450 | 2 | 9000 | 2*180 | 380 | 25 | 19 | |
FNH-29/100 | 29000 | 100 | 500 | 2 | 13140 | 2*450 | 380 | 25 | 19 | |
FNH-32/110 | 31900 | 110 | 500 | 2 | 13140 | 2*450 | 380 | 30 | 19 | |
FNH-35/120 | 34800 | 120 | 550 | 2 | 17440 | 2*600 | 380 | 30 | 19 | |
FNH-39/135 | 39150 | 135 | 550 | 2 | 17440 | 2*600 | 380 | 30 | 19 | |
FNH-45/155 | 44950 | 155 | 600 | 2 | 21640 | 2*780 | 380 | 30 | 22 | |
FNH-49/170 | 49300 | 170 | 600 | 2 | 21640 | 2*780 | 380 | 30 | 22 |
Model | copper tubes | Dimensions | Mounting dimensions | Coupling dimensions | Dimensions of fan arrangement | |||||||
Row numbe × Number of rings |
L | B | H | D | E | C | A | K | G | P | M | |
N×W | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | |
FNH-0.6/2 | 2×4 | 250 | 120 | 240 | 275 | 70 | 9 | 200 | 24 | 115 | 125 | |
FNH-1.0/3.4 | 3×4 | 250 | 120 | 240 | 275 | 70 | 9 | 200 | 24 | 115 | 125 | |
FNH-1.2/4.0 | 3×4.5 | 300 | 120 | 255 | 290 | 90 | 6 | 225 | 24 | 128 | 150 | |
FNH-1.3/4.4 | 3×5 | 325 | 120 | 280 | 290 | 70 | 6 | 250 | 24 | 140 | 162 | |
FNH-1.5/5.2 | 3×6 | 370 | 130 | 340 | 370 | 100 | 6 | 290 | 25 | 170 | 185 | |
FNH-2.0/7 | 4×6 | 370 | 150 | 340 | 370 | 120 | 6 | 290 | 25 | 170 | 185 | |
FNH-2.4/8.4 | 3×6 | 450 | 170 | 350 | 475 | 120 | 9 | 275 | 44 | 175 | 225 | |
FNH-3.1/10.6 | 4×6 | 450 | 170 | 350 | 475 | 120 | 9 | 275 | 44 | 175 | 225 | |
FNH-2.9/10 | 3×8 | 450 | 170 | 420 | 475 | 120 | 9 | 375 | 30 | 210 | 225 | |
FNH-3.5/12 | 4×8 | 440 | 180 | 420 | 430 | 130 | 9 | 320 | 50 | 210 | 220 | |
FNH-4.4/15 | 4×9 | 490 | 180 | 470 | 480 | 130 | 9 | 370 | 50 | 235 | 245 | |
FNH-5.2/18 | 4×10 | 530 | 180 | 520 | 520 | 130 | 11 | 420 | 50 | 260 | 265 | |
FNH-6.4/22A | 5×10 | 530 | 200 | 520 | 520 | 150 | 11 | 420 | 50 | 260 | 265 | |
FNH-7.8/27 | 6×9 | 590 | 240 | 470 | 580 | 190 | 11 | 425 | 35 | 240 | 295 | |
FNH-6.4/22B | 4×8 | 810 | 180 | 420 | 800 | 130 | 11 | 320 | 50 | 210 | 210 | 400 |
FNH-8.1/28 | 4×9 | 890 | 180 | 470 | 880 | 130 | 11 | 420 | 50 | 260 | 220 | 430 |
FNH-9.6/33 | 4×10 | 940 | 180 | 520 | 930 | 130 | 11 | 420 | 50 | 260 | 240 | 450 |
FNH-12.2/42 | 5×10 | 940 | 200 | 520 | 930 | 150 | 11 | 420 | 50 | 260 | 240 | 450 |
FNH-15/52 | 5×12 | 940 | 200 | 620 | 930 | 150 | 11 | 500 | 50 | 310 | 240 | 450 |
FNH-17/60 | 5×12 | 1160 | 240 | 620 | 1150 | 170 | 11 | 500 | 50 | 310 | 220 | 560 |
FNH-20/70 | 4×14 | 1160 | 240 | 720 | 1150 | 190 | 11 | 500 | 50 | 360 | 240 | 560 |
FNH-23/80 | 4×16 | 1160 | 240 | 820 | 1150 | 190 | 11 | 500 | 50 | 410 | 220 | 560 |
FNH-29/100 | 4×17 | 1350 | 260 | 870 | 1340 | 210 | 11 | 500 | 50 | 435 | 240 | 660 |
FNH-32/110 | 4×18 | 1350 | 260 | 920 | 1340 | 210 | 11 | 500 | 50 | 460 | 240 | 660 |
FNH-35/120 | 4×20 | 1350 | 260 | 1020 | 1340 | 210 | 11 | 500 | 50 | 510 | 240 | 660 |
FNH-39/135 | 5×18 | 1350 | 260 | 920 | 1340 | 210 | 11 | 500 | 50 | 460 | 240 | 660 |
FNH-45/155 | 5×20 | 1400 | 300 | 1020 | 1390 | 250 | 11 | 500 | 50 | 510 | 240 | 680 |
FNH-49/170 | 5×22 | 1400 | 300 | 1120 | 1390 | 250 | 11 | 500 | 50 | 560 | 240 |
680 |
Recommended Products
Center
INVOTECH YM/YSM series Scroll compressor
NTZ108 5hp refrigeration equipment freezer cold room condensing unit NTZ108
KUB-4DES-7Y*2 Shanghai KUB factory R404A R507 R134A refrigerant 4DES-7Y compressor refrigeration condensing unit paralle
KUB1500 15HP cascade 12HP compressor Ultra-low temperature cold storage refrigeration unit cascade unit condensing unit
CONTACT US
Address: Building 4, No. 328 Hengyong Road, Jiading District, Shanghai
Mailbox:lucy@shkubao.com/kub@shhkubao.cn
Phone:021-63272638
Fax:021-53750132
Copyright © 2021 Shanghai Baoku refrigeration equipment 沪ICP备14033466号-1